
汽车内装配备和舒适应用不断的在升级,从而提高驾驶员和乘客的舒适度和安全。
汽车内装配备和舒适应用不断的在升级,从而提高驾驶员和乘客的舒适度和安全。影音视觉系统包括导航、抬头显示器、环景系统、倒车显影等主要作用是提高驾驶员对周围车辆和环境的掌握,提升驾驶安全;座椅记忆、自动温度控制系统(HVAC)降低驾驶员的驾驶疲劳度;车载资讯娱乐系统逐渐于物连网连结,增加了乘客的乘车体验。强茂针对汽车车身应用和车载资讯娱乐系统亦提供一系列解决方案,不论是用于LIN bus和CAN bus上,保护资讯传输的ESD,或是电源电路的H Type Schottky和MOSFET元件。
电路拓扑

-
PEC3808CS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
-
PEC3808AS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
-±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3808C2E-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3808C2C-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3808C2A-AU
• ISO10605(C=330pF, R=330Ω) :
±30kV Air, ±30kV Contact for 8V ~ 24V
±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3812CS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3812AS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3812C2E-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3812C2C-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3812C2A-AU
• ISO10605(C=330pF, R=330Ω) :
±30kV Air, ±30kV Contact for 8V ~ 24V
±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3815CS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3815AS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3815C2E-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3815C2C-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard
-
PEC3815C2A-AU
• ISO10605(C=330pF, R=330Ω) :
±30kV Air, ±30kV Contact for 8V ~ 24V
±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3824CS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3824AS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3824C2E-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3824C2C-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3824C2A-AU
• ISO10605(C=330pF, R=330Ω) :
±30kV Air, ±30kV Contact for 8V ~ 24V
±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3836CS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3836AS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3836C2E-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3836C2C-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3836C2A-AU
• ISO10605(C=330pF, R=330Ω) :
±30kV Air, ±30kV Contact for 8V ~ 24V
±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard
-
PEC3808AS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
-±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3808C2E-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3808C2C-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3808C2A-AU
• ISO10605(C=330pF, R=330Ω) :
±30kV Air, ±30kV Contact for 8V ~ 24V
±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3812CS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3812AS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3812C2E-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3812C2C-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3812C2A-AU
• ISO10605(C=330pF, R=330Ω) :
±30kV Air, ±30kV Contact for 8V ~ 24V
±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3815CS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3815AS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3815C2E-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3815C2C-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3815C2A-AU
• ISO10605(C=330pF, R=330Ω) :
±30kV Air, ±30kV Contact for 8V ~ 24V
±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3824CS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3824AS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3824C2E-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3824C2C-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3824C2A-AU
• ISO10605(C=330pF, R=330Ω) :
±30kV Air, ±30kV Contact for 8V ~ 24V
±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3836CS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3836AS-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3836C2E-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3836C2C-AU
• ISO10605(C=330pF, R=330Ω) :
- ±30kV Air, ±30kV Contact for 8V ~ 24V
- ±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
PEC3836C2A-AU
• ISO10605(C=330pF, R=330Ω) :
±30kV Air, ±30kV Contact for 8V ~ 24V
±25kV Air, ±20kV Contact for 36V
• HBM ≧ ±8KV & CDM ≧ ±2KV
• ISO7637-3
• IEC61000-4-5(Lightning) : 8~1.5A(8/20uS)
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard
-
MER2DAL-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER2DAH-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER3DAH-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER2DAFC-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER3DAFC-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER2DBF-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER3DBF-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER1DMA-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER2DMA-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER3DMA-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER1DMB-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER2DMB-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard -
MER3DMB-AU
• Superfast recovery times-epitaxial construction
• Low forward voltage, high current capability
• Low leakage
• AEC-Q101 qualified
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard
推荐产品
资料载入中
